Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38686539

RESUMO

Artemisinin is the leading medication for the treatment of malaria and is only produced naturally in Artemisia annua. The localization of artemisinin in both the glandular and non-glandular trichomes of the plant makes it an ideal candidate for mass spectrometry imaging (MSI) as a model system for method development. Infrared matrix-assisted laser desorption electrospray ionization MSI (IR-MALDESI-MSI) has the capability to detect hundreds to thousands of analytes simultaneously, providing abundance information in conjunction with species localization throughout a sample. The development of several new optical trains and their application to the IR-MALDESI-MSI platform has improved data quality in previous proof-of-concept experiments but has not yet been applied to analysis of native biological samples, especially the MSI analysis of plants. This study aimed to develop a workflow and optimize MSI parameters, specifically the laser optical train, for the analysis of Artemisia annua with the NextGen IR-MALDESI platform coupled to an Orbitrap Exploris 240 mass spectrometer. Two laser optics were compared to the conventional set up, of which include a Schwarzschild-like reflective objective and a diffractive optical element (DOE). These optics, respectively, enhance the spatial resolution of imaging experiments or create a square spot shape for top-hat imaging. Ultimately, we incorporated and characterized three different optical trains into our analysis of Artemisia annua to study metabolites in the artemisinin pathway. These improvements in our workflow, resulted in high spatial resolution and improved ion abundance from previous work, which will allow us to address many different questions in plant biology beyond this model system.

2.
Rapid Commun Mass Spectrom ; 38(9): e9725, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38456255

RESUMO

RATIONALE: Mass spectrometry imaging (MSI) elevates the power of conventional mass spectrometry (MS) to multidimensional space, elucidating both chemical composition and localization. However, the field lacks any robust quality control (QC) and/or system suitability testing (SST) protocols to monitor inconsistencies during data acquisition, both of which are integral to ensure the validity of experimental results. To satisfy this demand in the community, we propose an adaptable QC/SST approach with five analyte options amendable to various ionization MSI platforms (e.g., desorption electrospray ionization, matrix-assisted laser desorption/ionization [MALDI], MALDI-2, and infrared matrix-assisted laser desorption electrospray ionization [IR-MALDESI]). METHODS: A novel QC mix was sprayed across glass slides to collect QC/SST regions-of-interest (ROIs). Data were collected under optimal conditions and on a compromised instrument to construct and refine the principal component analysis (PCA) model in R. Metrics, including mass measurement accuracy and spectral accuracy, were evaluated, yielding an individual suitability score for each compound. The average of these scores is utilized to inform if troubleshooting is necessary. RESULTS: The PCA-based SST model was applied to data collected when the instrument was compromised. The resultant SST scores were used to determine a statistically significant threshold, which was defined as 0.93 for IR-MALDESI-MSI analyses. This minimizes the type-I error rate, where the QC/SST would report the platform to be in working condition when cleaning is actually necessary. Further, data scored after a partial cleaning demonstrate the importance of QC and frequent full instrument cleaning. CONCLUSIONS: This study is the starting point for addressing an important issue and will undergo future development to improve the efficiency of the protocol. Ultimately, this work is the first of its kind and proposes this approach as a proof of concept to develop and implement universal QC/SST protocols for a variety of MSI platforms.

3.
J Am Soc Mass Spectrom ; 34(5): 869-877, 2023 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-36988291

RESUMO

Numerous preparatory methods have been developed to preserve the cellular and structural integrity of various biological tissues for different -omics studies. Herein, two preparatory methods for mass spectrometry imaging (MSI) were evaluated, fresh-frozen and sucrose-embedded, paraformaldehyde (PFA) fixed, in terms of ion abundance, putative lipid identifications, and preservation of analyte spatial distributions. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI)-MSI was utilized to compare the preparatory methods of interest with and without the use of the conventional ice matrix. There were 2.5-fold and 1.6-fold more lipid species putatively identified in positive- and negative-ion modes, respectively, for sucrose-embedded, PFA-fixed tissues without an ice matrix relative to the current IR-MALDESI-MSI gold-standard, fresh-frozen tissue preparation with an exogenous ice matrix. Furthermore, sucrose-embedded tissues demonstrated improved spatial distribution of ions resulting from the cryo-protective property of sucrose and paraformaldehyde fixation. Evidence from these investigations supports sucrose-embedding without ice matrix as an alternative preparatory technique for IR-MALDESI-MSI.


Assuntos
Lipidômica , Espectrometria de Massas por Ionização por Electrospray , Camundongos , Animais , Espectrometria de Massas por Ionização por Electrospray/métodos , Gelo , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Íons/química , Lipídeos/análise , Encéfalo
4.
J Mass Spectrom ; 58(3): e4911, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36916455

RESUMO

The field of mass spectrometry imaging (MSI) is constantly evolving to analyze a diverse array of biological systems. A common goal is the need to resolve cellular and subcellular heterogeneity with high spatial resolution. As the field continues to progress towards high spatial resolution, other parameters must be considered when developing a practical method. Here, we discuss the impacts of high spatial resolution on the time of acquisition and the associated implications they have on an MSI analysis (e.g., area of the region of interest). This work presents a brief tutorial serving to evaluate high spatial resolution MSI relative to time of acquisition and data file size.


Assuntos
Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
5.
J Mass Spectrom ; 58(2): e4904, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36740651

RESUMO

Mass spectrometry imaging (MSI) is an important analytical technique that simultaneously reports the spatial location and abundance of detected ions in biological, chemical, clinical, and pharmaceutical studies. As MSI grows in popularity, it has become evident that data reporting varies among different research groups and between techniques. The lack of consistency in data reporting inherently creates additional challenges in comparing intra- and inter-laboratory MSI data. In this tutorial, we propose a unified data reporting system, SMART, based on the common features shared between techniques. While there are limitations to any reporting system, SMART was decided upon after significant discussion to more easily understand and benchmark MSI data. SMART is not intended to be comprehensive but rather capture essential baseline information for a given MSI study; this could be within a study (e.g., effect of spot size on the measured ion signals) or between two studies (e.g., different MSI platform technologies applied to the same tissue type). This tutorial does not attempt to address the confidence with which annotations are made nor does it deny the importance of other parameters that are not included in the current SMART format. Ultimately, the goal of this tutorial is to discuss the necessity of establishing a uniform reporting system to communicate MSI data in publications and presentations in a simple format to readily interpret the parameters and baseline outcomes of the data.


Assuntos
Projetos de Pesquisa , Espectrometria de Massas/métodos , Íons , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
6.
Metabolites ; 12(11)2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36355179

RESUMO

Amyotrophic lateral sclerosis (ALS) is an idiopathic, fatal neurodegenerative disease characterized by progressive loss of motor function with an average survival time of 2-5 years after diagnosis. Due to the lack of signature biomarkers and heterogenous disease phenotypes, a definitive diagnosis of ALS can be challenging. Comprehensive investigation of this disease is imperative to discovering unique features to expedite the diagnostic process and improve diagnostic accuracy. Here, we present untargeted metabolomics by mass spectrometry imaging (MSI) for comparing sporadic ALS (sALS) and C9orf72 positive (C9Pos) post-mortem frontal cortex human brain tissues against a control cohort. The spatial distribution and relative abundance of metabolites were measured by infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MSI for association to biological pathways. Proteomic studies on the same patients were completed via LC-MS/MS in a previous study, and results were integrated with imaging metabolomics results to enhance the breadth of molecular coverage. Utilizing METASPACE annotation platform and MSiPeakfinder, nearly 300 metabolites were identified across the sixteen samples, where 25 were identified as dysregulated between disease cohorts. The dysregulated metabolites were further examined for their relevance to alanine, aspartate, and glutamate metabolism, glutathione metabolism, and arginine and proline metabolism. The dysregulated pathways discussed are consistent with reports from other ALS studies. To our knowledge, this work is the first of its kind, reporting on the investigation of ALS post-mortem human brain tissue analyzed by multiomic MSI.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...